• 回答数

    3

  • 浏览数

    258

KellyYin0816
首页 > 学术期刊 > 有害气体浓度检测系统设计论文

3个回答 默认排序
  • 默认排序
  • 按时间排序

黑糖miko

已采纳

With the diversity of social and economic development, buildings, structures, Applied Materials, the development of various industrial and science and technology, increase in combustible materials, coupled with people's living environment and lifestyle changes, the risk of fire is increasing, the number of firescasualties and economic losses caused by fire is gradually increasing. Fire as the enemy of endangering the survival of mankind, more attention has been paid. With the growing number of high-rise buildings, fire hazards increase. Event of fire, will people's lives and property caused great harm, so people began to seek a method of early detection of fire, in order to control and extinguish fires and to minimize losses, protect life safety.With the development of electronic science and technology, electronics technology has become a powerful means of security, many security aspects of electronic products, the right-hand man of the people's lives. This design uses a microcontroller technology with A / D conversion chip to build a combustible gas detector alarm. When the leak of flammable or toxic gases in the environment to the critical point of the combustible gas concentration reaches the alarm set, when the gas alarm detection, combustible gas alarm will send alarm signal to remind staff to take safety measures. This paper briefly describes the design combustible gas detection alarm as well as the advantages of the SCM system; then details the design flow of the combustible gas detection alarm, as well as hardware and software systems design and software programming detailed steps, including the various modules of the program design and system debugging and simulation steps, results.The design uses the MQ-2 gas sensor signal acquisition tool as a combustible gas, the collected analog voltage after the ADC0809 converted into digital signals. Single-chip digital signal acquisition to the ADC0809 has been calculated, if the combustible gas concentration reaches the critical point when the alarm is set microcontroller will drive the LED and buzzer alarm signal. In the case of non-combustible gases, the occurrence of unknown danger, the alarm can artificially control buttons to change the fire alarm initial value. 希望能帮到你

255 评论

钮咕噜嘟嘟

: with the development of social economy, buildings, structures the diversity of applied materials, all kinds of industry and the development of science and technology, flammable material increased, together with people living environment and lifestyle changes, increasing the risk of fire, fire, the fire caused the number of casualties and economic loss increase gradually. Fire is harmful to human survival as the enemy of, more and more attention by people. With the increasing of the high-rise building, fire hidden trouble increase. Once the fire, and will be of the lives and property of the people do great harm, so people begin to seek a kind of early detection method of fire, in order to control and extinguish fire, reduce loss, and safeguarding the safety of life.With the introduction of the development of science and technology, electronic technology to become effective means of the safety aspects of, many, many of the safety aspects of electronic products, is the life of people's right-hand man. This design using single chip computer technology with A/D conversion chip constructed A flammable gas detection alarm. When environment flammable or poisonous gas leak, when gas alarm detect combustible gas concentration reach the point of alarm Settings, flammable gas alarm will be issued a warning signal to remind workers to take security measures. This paper firstly introduces the design flammable gas detection alarm the main way and the advantage of single-chip microcomputer system; And then introduced the flammable gas detection alarm design process, and the hardware and software design of the system, and gives the software program design detailed steps, including each module of the program design and the whole system commissioning and simulation steps, the results.This design USES MQ-2 gas sensor as flammable gas the signal acquisition tools, the collected simulation voltage quantity after ADC0809 into digital signals. Single chip ADC0809 collection to the digital signal after calculation, if combustible gas concentration reach the point of single chip set alarm when will drive LED and a buzzer issued a warning signal. In no RanQiTi, some unknown risk, alarm can human control key change fire alarm initial value.

325 评论

枫桥夜泊123123

我能写室内有害气体监测系统的设计的毕业论文,原创

94 评论

相关问答

  • 轴承精度检测系统设计论文

    需要的话联系我吧[1]刘健. 面向轴承制造过程的制造执行系统(MES)的研究与开发[D]. 浙江大学: 浙江大学,2007.[2]欧阳,. 轴承制造的几个关键技

    飛天彩绘 1人参与回答 2023-12-07
  • 有害气体浓度检测系统设计论文

    With the diversity of social and economic development, buildings, structures, Ap

    KellyYin0816 3人参与回答 2023-12-05
  • 酒精浓度检测仪的设计毕业论文

    当具有N型导电性的氧化物暴露在大气中时,会由于氧气的吸附而减少其内部的电子数量而使其电阻增大。其后如果大气中存在某种特定的还原性气体,它将与吸附的氧气反应,从而

    那个啥来着呢 4人参与回答 2023-12-06
  • 湿度检测系统设计论文

    来我公司实习吧,在北京

    蒋大女儿 6人参与回答 2023-12-07
  • 汽车尾气检测系统设计论文

    汽车环保毕业论文 汽车的节能与环保是目前我们急剧解决的社会问题,汽车尾气污染已占大气污染的百分之七十,汽车尾气排放已成为我们的首要污染源。下面为大家分享了汽车环

    小菜菜菜菜子 4人参与回答 2023-12-05