MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 1.给排水设计 饮用水和污水 Design Water and sewage water .设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 .Design bases Design Brief and Municipal integrated network drawing offered by the client. Condition drawings from architectural discipline. Current national design codes and related stipulations 2. 给水系统 通过一根DN200的进水管将水引入.水表安装在进水管上,离红线1米处.供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池.由环路管网向必需的室外消火栓和绿化带的喷淋器供水. 2. Water supply system For water supply of this project, DN200 water intake pipes are led in. Water meters are installed on the intake pipes m away from the red line. The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings respectively. Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop networks. 设计范围 包括红线内的饮用水,污水,雨水,建筑消防. Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red line. 给排水水池与消防水池分开,容量为100m3 .体操馆供水管埋地敷设. Sanitary water pool is separated from fire water pool, volume of sanitary water pool is 100m3. Water supply pipes for the stadium will be laid in the earth. 3.用水量标准 - 体育馆: 15升/顾客·日 K= - 宾馆: 150升/人·日 K= - 餐厅: 50升/顾客·日 K= - 工作人员: 25升/人·日 K= - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K= - Hotel: 150L/visitor·day K= - Restaurant: 50L/customer·day K= - Staff 25L/person·day K= - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water consumption. Unforeseen water consumption: 20% of the daily water consumption. Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: ·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机.为此饮用水系统安装循环泵.机房 设在地下室的水除了机房.当饮用水机不被使用时,应排空,以免水质腐败. 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵. 在更衣间旁设置电热水器,为淋浴和洗盥供应热水. 为楼板清洁安装一定数量的水龙头. Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the basement. When there is no use, portable water will be drained completely to avoid deterioration. Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot water. Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and washing. Certain number of water taps are installed for floor-cleaning. 4.用水量 最大日用水量:日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统.总冷却水用量为460m3/h.在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h).进水温度37Co,出水温度32Co .补充水量 9,6 m3/h.补充水由市政供水网直接提供. Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation system. Total water consumption of cooling towers is 460m3/h. On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/h. Make-up water of the cooling towers will be supplied directly by the municipal network. 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用).用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心. 消防水箱和消防稳压装置分别安装在车库的四面墙. In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby). Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, etc. are provided in fire equipment centers. Four fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the garages. 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: ·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米.消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱.室内消火栓系统在室外设有三组水泵接合器. Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than 30m. Hydrant networks are connected as a loop both horizontally and vertically. Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are provided. Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is installed. There are three sets of pump adopters being installed outdoors for the indoor hydrant system. 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓.两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池.消防水池总容量不应小于4000m3, 每个为. Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are water supply pipes (DN200) are led into the fire water pools at each fire water pump room in supplybuilding. In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is . 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间.喷淋泵安装在地下的消防泵房内.报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内. Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump rooms. Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire compartments. 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统.餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头.三组泵接合器安装在室外. Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground garage. Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are provided. Three sets of pump adaptors for this system will be installed outdoors. 排水系统 为排水系统设置污水主立管和特别垂直排气管.排气管与污水管在每层连接,污水排出体操馆.餐厅的污水首先在油脂分离池中处理,然后排入室外排水网.给排水污水将被在化粪池收集和处理,然后排入市政排水管网.化粪池在输送区旁.最大天排水量为870m3/天. 9. Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage system. The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of stadium. Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage networks. Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal drainage. The septic tanks are located besides the deliverycircle. Maximum daily drainage amount is 870m3/day. 卷帘水幕系统 地下车库设置有卷帘水幕系统.水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制.十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and manually. Ten pump adapters will be installed outdoors for this system. 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制. 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网. There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage pumps. Operation of the pumps is controlled by the magnetic floating ball controllers. Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater networks. 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统. Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment rooms. 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器. According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant box. 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外. Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the pumps. 雨水系统 雨水排水屋顶采用压力流排水. 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=(1+)/(t+)计算. 沿柱在屋面设置雨水沟.雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井. 10. Rainwater system Pressurized drainage system is adopted for roof rainwater drainage system. Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=(1+)/(t+) Rainwater gutters are provided on roof along columns, skylight. Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection wells. 11.管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接. - 直饮水管采用不锈管. - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接. - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接. -二氧化碳管采用无缝钢管焊接. - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接. Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling towers. Stainless stell pipes are adopted for portable water pipes. Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction pipes. Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler pipes. Seamless steel pipes connected by welding are selected for CO2 pipes. Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground garage. 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放.雨水被收集,然后排入市政集水池. When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the eaves. Rainwater is collected, and then drained to the municipal catch basins. 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池. 此池将作为一个循环过滤设施,可容水约 m . 喷洒压力设备和其它必须的过滤设备安装在供应楼里. The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor greening. The pool will be used as a circular filtering facility and will be adopted with a water volume of about m . The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply building. 制冷 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房.空调设计日峰值冷负荷为,设计日总冷负荷为3 kW. Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary rooms. Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW. 每台1200kW制冷机配一台 流量为206m3/h离心泵.各配一台备用泵 一次泵采用压差旁路控制. 通过埋地敷管,向游泳体操馆供应冷冻水. A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW chiller. One operation pump with a standby corresponds to one chiller. Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be deliverded. 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房.设计容量为4800kW. 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%.而另2 台.每台出力为总设计容量的25%. 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等.冷冻水的供/回水温度为-7/ 12°C. Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW. For actuing in an energy efficient way one chiller about 50% of total capacity ( kW) and two chillers with 25% of total (600 kW each)capacity each are adopted. Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, etc. supply/return temperature of the chiller is-7/ 12°C. 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路. 二次泵采用变频调速控制.根据负荷侧供回水管的压差,控制水泵的转速. 二次泵循环支路的管道采用异程式. Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use functions. Variable-frequency speed-regulating control is adopted for secondary pumps. The rotating speed of a water pump is controlled according to the pressure difference between water supply and return pipes. Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统. Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump system. 管材: 水管采用焊接钢管及无缝钢管. 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作.每节风管之间用法兰连接. Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel pipes. Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil construction. Air ducts are connected together by flanges. 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/h.配一台备用泵. Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW chiller. One operation pump with a standby corresponds to one chiller. 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温. 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温. - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充. Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate pipes. Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after chillers. Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go through. 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪. 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接. - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离. Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower noise. Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and ventilators. Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their pipes. 空调和通风系统 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统.这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区. 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are used. These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

166 评论

头发长很慢

给排水工程对城市发展建设有着重要意义,因为给排水会影响到城市居民正常生活和社会稳定。下面是我为大家整理的给排水相关论文,供大家参考。

【摘要】看一个城市是否发达,不光要看GDP、高楼大厦,还要看人们看不到的地方,比如下水道等;看一个城市的规划是否合理,不仅要看楼间距、绿化程度,还要看人们需要的地方,比如给排水系统。给排水设计在城市规划中占有十分重要的地位,对满足城市居民的基本生活与工农业生产的供水、排水系统建设具有很重要的意义。

【关键词】城市规划,给水,排水

一、引言

城市给排水工程是对城市给水排水工程系统的统一安排,保证给水排水工程建设与城市发展相协调,促进城市的可持续发展。它是城市规划中的一项专业规划,也是城市整体开发建设的一个重要组成部分。它的综合作用是不能被代替的。城市水系统的规划与设计是否合理将直接影响和制约城市的发展。“城市水系统”主要包括水源系统、用水系统、给水系统、排水系统、回用系统和 雨水 系统。随着城市的发展,各个城市间的给排水工程不再是一个孤立的系统,水域把这些子系统连接为一个系统,原有的工程规划 方法 在一定程度上显示其局限性,这就要求我们在新的历史条件下做好城市市政给排水规划设计,认真思考与解决现存的问题,寻求城市水资源的合理利用,在经济和技术方面满足社会发展的要求,实现现代化城市的可持续发展。

二、城市给排水系统规划存在的问题

(1)市政给排水工程规划滞后。在市政道路排水工程设计过程中,给排水工种处于配合地位,影响了城市给排水规划科学化的发展。往往出现道路要求快速建设,造成了排水工程规划没有编制,一些排水工程往往不能与道路工程同期施工;有的虽然设计完成后,排水工程规划由于相关原因需要修改,许多工程项目未能按照规划进行建设,规划的指导意义也没有得到真正体现,造成了工程需要再次改造。

(2)规划的科学依据不足。城市水系统规划的基础性工作主要包括各类指标、标准、基础数据和分析工具,其中水量预测和水平衡分析是核心工作。目前,我国的水量预测工作主要是参照《城市给水工程规划规范》(GB50282-98)中有关规定,但我国不论在国家还是在区域层次上都缺乏对用水工艺、各种用水器具和用水行为的详实系统监测,缺乏对新型用水技术替代规律和扩散规律的基础研究,缺乏对多种用水信息的综合性和结构性分析。

(3)排水体制规划混乱、排水体制的不合理。目前绝大部分市区的排水设施分别由环保局、市政工程管理处、水利局等不同部门管理,由于各部门之间沟通不够,管理人员责任不清,加之相关法律法规不够健全,对排水设施存在的问题以及发生的新问题都不能及时解决。另外传统的防洪和排水设施设计中,强调采用分流制排水体制将雨水和污水尽快排出城市,但忽视了城市径流面源污染的控制和雨水资源的利用。随着流域整体水质的逐步改善,城市随机性暴雨径流和突发排放事件引起的对水体生态系统的冲击,已日益成为流域污染控制的主要内容。

(4)传统的给排水专业不能满足市场的需要。由于城市给排水规划设计技术参数多、不定因素多,且具有交叉学科的特点,这使城市给排水规划的难度大大增加,刚从传统的给排水专业 毕业 的学生,因受知识结构的限制,不能进行宏观的分析论证,不适应城市规划多学科、多层次的分析论证要求,远不能满足城市给排水规划设计的需要。

三、解决城市给排水系统规划问题的对策

(1)城市水系统规划要与城市规划的协调。城市水系统规划是对一定时期内城市的水源、供水、用水、排水、污水处理等子系统及其各项要素的综合布置。城市用水规划的总量平衡非常重要,必须优化组合各种可行的节水、水回用等方案。要做到这些,首先要了解城市水利用规划,加强城市总体规划中的水专项规划,按照水的可持续发展观念编制城市水利用规划,内容应包括:地面水、地下水、雨水和海水等水资源平衡;供水、排水和污水再生利用等总量平衡;供水节水规划和污水处理与再生利用规划;水的生态循环规划;各类水工程设施的规模和布局等。对当前我国的城市水系统建设中普遍出现的规划不协调、建设不配套、管理不统一等问题,规划中要特别注意管网配套和供水、排水及污水处理能力的协调增长,确定规划期内水系统及其网络设施建设的规模、详细布局和运行管理方案。

(2)加强水量规模预算。水量预测是给水规划的基础,水量规模预测是否符合发展趋势和实际需要,对水资源的工程总体布局、合理利用、实施步骤和工程费用产生重大影响。国家标准《城市给水工程规划规范》是测算城市总用水量规模的主要依据,具体包括:总体规划阶段给水水量预测;总体规划阶段污水水量预测;分区规划阶段及专业规划给水、污水量预测;详细规划阶段给水、污水量预测。改革开发以来,工业生产、城市建设、住宅建设、第三产业迅速发展,使供水量也不断增长。作为城市基础设施之一的供水量的增长规律也将与过去不同,水量预测就不能仅按历史的发展计算,还要根据具体的城市规划对不同类型用水量分别进行预测分析。

(3)城市给排水系统应当向可持续性方向发展。自然界的水是循环的,给水和排水是统一的,人类社会对水的使用应服从这一过程。在用水之后,必须对水进行再生处理,使水质达到自然界自净能力所能承受的程度,否则累积的大量污染物将超过水环境的容量,从而导致水资源危机和水污染现象,最后破坏水的良性循环,不利于城市的可持续发展。控制城市给排水系统向可持续性方向发展的途径有:①在城市水系统中增加节水子系统;②在城市水系统中增加治污子系统;③在城市水系统中增加再生水回用子系统。加强节水、治污和再生水回用力度,重视再生水、中水等非传统水资源利用,是促进城市给排水系统良性循环,实现城市水资源可持续发展的关键。

(4)完善各项法规。根据我国当今给排水体制规划混乱的现状,应通过行政立法,完善相关法规,建立明确的给排水工程建设及管理职责制度和相关体系,明确管理权限,形成规划、建设、维护、监督各部门明确的权利、职责和监管机制。

四、结束语。在现代城市整体规划中,给排水的设计是一项十分重要的工作内容。城市规划是为了对资源进行优化配置,给排水工程规划重点是对水资源进行优化配置和合理利用,以发挥最大的综合效益。城市给排水设计是否合理、完善,直接关系着城市的经济建设和人民的基本生活需求。因此,在规划与设计城市给排水规划时要善于发现问题,并妥善处理好城市发展中可能面临的水资源、水环境、水灾害问题。高质量地编制好城市给排水规划,不仅是排水工程规划与设计自身的需要,而且是城市面向未来,走上可持续发展之路的保障。

摘 要:市政给排水管道施工质量随时影响着城市居民的生活,为了保证市政排水施工的质量,做好给排水施工的安全 措施 与防范是我们的首要任务。市政排水工程一旦出现问题将会对市民产生很大影响,而且出现市政给排水工程的问题和解决问题都需要较长的时间。从技术方面分析市政给排水工程的控制质量,确保给排水系统功能的正常发挥,能够及时防范在施工过程中出现的一些障碍,保证施工的正常进行。

关键词:市政;给排水;施工质量

随着人民生活水平的不断提高与社会经济的不断发展,对市民用水的便捷性也提出了新的要求,因此市政给排水工程也成为市政建设不可忽视的一项工程。城市的建设发展离不开给排水管道工程建设,为保证城市稳步的发展,因此在市政工程施工过程中提高其施工技术和施工质量是关键一环。在其城市化水平的不断提高与发展的过程中,给排水工程对城市环保以及城市防洪排涝等都有直接的影响,因此对其施工技术要求也日益增加。给排水管道工程施工质量出现问题,可能会造成污水倒流,在雨季会由于排水不畅而在城市中形成内涝给人民的日常生活带来极大的不便,同时有损政府形象。加强市政工程给排水管道施工质量的监管与控制,对于城市水污染的治理以及水资源的节约利用具有重大的意义。

1 市政给排水施工

施工准备阶段。市政给排水工程项目是城市规划建设与发展的重要保障。作为城市建设的基础项目其质量的安全可靠关乎城市的形象,而且由于市区施工环境复杂,其地下结构也存在着许多地下管线。同时容易受到各种因素的干扰,给排水工程施工的难度大大增加。为了提高市政给排水管道系统的安全性和可靠性,不仅要对施工技术进行严格的要求,还要做好相应的准备工作,确保工程的施工质量。

(1)给排水管道工程施工前,应把各类进场技术人员、工种、材料和机具设备检查结果情况及现场施工条件等因素都要一一考虑进去。施工工艺、施工方案、组织措施以及准备工作关系到工程的顺利实施,做好准备工作是重中之重。工程施工前,工作人员要对设计的施工图纸等进行严格审核,应避免工程障碍对工程质量以及施工技术带来较大的影响。同时需要实地勘察现场的施工条件,根据事实设计图纸,尽量避免因设计与实际情况不符造成给后续施工加大工作量。施工人员要采用相关的技术手段对其可能存在的障碍进行全方位的调查与排除,避免施工中因地下出现各种管道与设计冲突而妨碍施工的现象。在专业图纸上,应明确施工要求,多方进行讨论与查漏补缺,纠正错误。

(2)管材质量是确保施工工程质量的基础,对各种管材之中容易出现的问题和缺陷进行严格控制,材料质量的优劣是影响其给排水功能正常有效发展的前提和关键。为有效防治和预防出现渗水和渗透问题应严格控制管材质量由专业的技术人员进行监管。施工过程中由于城市特有的特点交通繁忙设立必要的安全措施既是对工作人员的防护也是对市民出行安全的考虑。从可持续发展角度而言,在给排水工程中推广新型具有管道摩阻小、排水量大、重量轻、施工方便等特点塑料复合管材,符合国家以塑代钢政策。但限于国家的技术发展程度其使用材料也有可能对周围环境有一定的影响,因此我们除了积极克服技术问题,必要时还要和当地环境卫生部门进行相应的协商。

2 施工阶段

管槽开挖

在开挖之前,根据技术规范相关条款的规定做好原始地貌的中心线、高程、转角的原始记录。应该对地下既有管道,施工现场的电缆和其他构筑物存在的情况逐一查实探明,并标准它们的位置,为了保护其完好性以便于采取相应的保护措施。根据不同的土壤条件,开挖直槽、梯形沟槽、开挖混合管槽等不同的管槽,沟槽开挖宽度应根据开挖深度和管径大小确定。随着科学技术的不断提高,机械化施工技术水平有了很大的改善,机械施工取代了大量的人力劳动而成为工程施工的重要方法,人仍然是机械的操作者,应协调好人与机的关系,保质保量的完成施工。施工时应掌握天气变化, 防止沟槽内长期积水,形成浮管现象。考虑到基槽暴露时间过长会引起基槽变形的问题,要尽量缩短晾槽时间。在沟槽开挖将要结束时,应提前做好管道基础稳定准备,并对碎石形成的混凝土基础进行控制分析,及时处理施工过程中出现的各种质量隐患。严格按照标准铺设砂砾垫层并压实,在铺好的砂砾垫层上浇筑由设计人员按照工程实际情况和工程要求进行设计的具有一定刚度和稳定性性能的混凝土。因地面下的结构并非一成不变,防止机械化施工挖掘过量,一旦出现应及时进行回填和夯实,针对此出现的工作失误进行及时处理。

管道安装

管材进场后,由专门的技术人员检验合格后才能用于工程。为能够有效保证管路的密闭性需确保管材质量合格并确定密封胶圈完好现象。管道安装对接一般依靠管道顶部的外拉法和管道内部的内拉法,逐渐将两节管道对接在一起。为防止扰动基底管道相互碰撞需保证管节平稳的缓慢的下放,因此应有专人进行指挥铺管下管,管道放入后必须垫稳。具体方法可在 编织 袋内灌满砂石或黄砂,封口后压在已排设管道的顶部。进行管道铺设时确保管道表面无杂物,内部也干净。待管道铺设阶段完工后进行检测验收,检验结果合格后就可进行混凝土管座及接口施工。当接口合拢时为保证已排设管道轴线位置的稳定,需采取稳管措施,防止轴线出现偏移。管道接口后,应复核管道的高程和轴线使其符合要求。安装时使内壁平齐,对口准确。焊缝表面光顺、饱满、均匀,错口误差小于 倍壁厚。其宽度、表面余高、咬边、错边等均符合设计规范要求。对管道焊接质量要进行油渗试验和 X 射线无损探伤检测仪进行检测,检测合格后管道安装才算合格。

闭水试验

当管道安装完毕后,确保管道沟槽内无积水、预留孔洞均封堵且不漏水,有工作技术人员检查管道及检查井外观质量是否合格。若经检验合格,在对管槽进行回填前,应对重力流、设计要求闭水的管道以及压力管道都必须做水压试验。在排水管路施工质量检测的多种方法中,闭水实验对其施工质量的检测属于最直观、最有效的方法。将排水管道从上游向下游分段依次试验。试验满水浸泡一天之后,按照实验要求的试验水头达到规定水头,对管道不断渗水量观测持续半小时以上,实测渗水量是否满足排水管道闭水试验施工要求规范规定的允许渗水量。检查每一处管路的防漏性,是否存在渗水部位、漏点、裂缝等。闭水实验同时也可测定各管连接接口的密闭性,如发现有渗漏,应及时采取修补措施,可调制水泥浆对漏点处进行修补和填实。

3 市政给排水施工质量控制要点

在城市的市政给排水工程中,整个市政给排水工程质量控制的最重要环节是施工阶段。做好市政给排水工程施工质量的控制是对整个工程的安全措施的保障。为满足管道安装的所需条件,结合管道的设计要求及纵向位置适当调整该处的道路基础。给排水管道穿越软弱土地区时,压力管道一般采用柔性连接管道接口,以增强其变形能力, 同时进行适当的地基处理和防腐措施。对管道进行严格的防腐处理,应选用防腐性能好的管材产品。管槽开挖时要采取适当的技术措施,保护好地基处理成果不被破坏,并对回填土进行严格控制。

4 结语

为保证市政给排水施工质量,需要工程的负责人针对每个工程的施工环节都做到认真仔细严格把关。针对市政给排水工程在建设施工中的施工的技术和质量都要进行反复的检查,这关系到整个给排水工程的质量。采用科学先进的施工技术,这样才能够使给排水工程的施工质量得到有效地控制,才能够使市政排水系统在施工完成后能够正常有效地发挥其功能。同时借鉴国外的大城市给排水系统设计完善我国面临的难题,提高市政工程质量。

参考文献:

[1]张胜霜.浅析市政给排水施工质量控制技术[J].科技创新与应用,2014(08).

[2]潘政委.市政给排水管道工程施工优化探讨[J].中国新技术新产品,2011(22)

【摘 要】给排水工程施工管理主要以建设、施工项目作为管理对象,不断进行全面系统管理和优化的管理与控制活动,即是从施工项目开始到项目竣工完成过程中,通过一系列的项目控制与管理措施,以确保质量管理目标、成本管理目标以及安全管理目标的顺利实现。为全面保证施工质量,以下就给排水工程中的施工前、施工中以及施工后三个阶段分别进行了阐述。

【关键词】给排水工程;施工;管理

1.施工准备阶段

做好图纸会审工作

图纸会审是施工准备阶段的一项重要组成部分,做好图纸会审能有效促进给排水施工的正常进行。依据给排水工程的基本特点,应抓好以下几方面工作:设计图纸是否符合国家技术规范标准、当地相关政策的具体规定以及是否满足建设单位的基本要求;设计是否具备进行施工的技术条件,采取先进的技术措施和施工工艺时,是否能保证技术上的施工安全;设计图纸上坐标、标高和尺寸等是否符合实际建筑构件的要求,洁具设备的安装位置是否恰当,以及材料的规格、尺寸等是否合乎规定的基本要求;消防设备以及基础设施的具体位置应提前上报当地主管部门得到审查认可,并确定具体的施工要求;加强各专业之间的协调工作,做好土建预留、预埋孔洞和设备安装位置的技术交底工作。

加强施工组织设计

承包商应加强施工组织设计工作,并将具体施工方案提交给监理和业主进行审核。施工组织方案应突出体现设计图纸的可行性、合理性和安全性的基本原则,重点关注组织方案的技术和质量措施,是否完全符合 承包合同 规定的基本条件和具体要求,确保安全和文明施工并确保切实符合相关规范的有关规定;工程专业技术人员应认真掌握设计图纸内容,相关验收规范等,通过对承包商提交的施工组织设计进行严格的审查,审查对象主要是专业工程部分和承包商分包工程部分,详尽了解施工企业的综合技术和管理水平,以便进行有重点的预控和管理力度。

严格材料、设备质量控制

给排水施工所需材料、设备,在施工前由施工单位填写《工程材料使用报审表》,为保证材料、设备的质量以及各种性能指标符合技术标准要求,应安排采购部门统一进行采购和管理。应依据排水设计施工图规定的规格、型号等以及施工要求进行采购,所选购材料、设备必须具备合格证、质保书以及相关检测 报告 等相关认证资料,特殊材料需经相关质检部门检验合格后方可使用,所有运至施工现场的材料和设备,均必须做好防雨、防潮等保管防护工作。

2.施工阶段的管理工作

做好组织、协调和管理工作

给排水工程在建筑整体工程中占有相对较小的比重,但其涉及面广,工序复杂,专业工种多,因而必须加强组织、协调和管理工作。应严格混凝土浇筑的审批程序,由专业工程师进行现场指导,做好土建和给排水安装作业的协调配合,重点强调预留、预埋孔洞的具体位置和实际尺寸,以避免后续施工由于土建预留预埋的失误而开凿墙板造成返工。施工单位应及时和设计单位进行沟通,以便及时攻克施工过程中的诸多技术和管理问题,应严格控制设计的变更,设计变更必须经过多方周密细致分析讨论后实施。另外,必须经过给排水专业工程师签名确认后,方可进行混凝土的浇筑。

做好土建施工的预留、预埋工作

为防止后续施工进行楼板开凿而严重破坏建筑物结构,在进行土建施工时应将管道穿越楼板位置预留适当的孔洞,同时在管道穿越地下室外墙的具体位置,也必须预埋合适的套管,以避免外墙产生渗漏现象。因此,一定要严格和土建施工的密切配合,并确保管道穿越位置预留、预埋孔洞、支架以及钢构件等完全符合设计要求。应确保预埋在管道穿越楼板处套管的顶部比装饰地面高出20mm的距离,预埋在厨房、卫生间内的套管的顶部应比装饰地面高出50mm的距离,同时应使套管底部保持和楼板底面齐平,预埋在穿越墙壁位置的套管,保持其两端和饰面齐平,禁止随意开凿孔洞。依据设计施工图纸的基本要求,认真掌握管道配件的尺寸大小,在进行混凝土浇注前应制出预留套管的样图,作为指导预埋预留孔洞施工的参考依据。

做好主体结构的装修施工

进行主体结构装修施工是给排水工程施工中的重要环节,管道穿越主体结构的伸缩缝、沉降缝等后浇带时必须安装补偿装置。安装立管之前,需要将该立管在各部位预留预埋孔洞打通,由上往下垂直吊线,并准确测出立管的垂直中心线作为安装立管的参照线。立管施工完毕后,应严格检查其是否合乎垂直度和墙之间的距离比例要求,是否合乎设计施工的具体要求,待确定一切达到标准后利用管卡将其固定,并按照设计施工规范要求将各位置孔洞修补平整。排水立管应依照设计规定,在其中心位置距地面大约为处设置检查口,同时应在排水立管底部按具体要求设置合适的支墩。套管和管道之间的缝隙采用阻燃细密材料进行填实至端面平滑为止,并确保管道接口不要设置在套管内。吊顶内以及墙体内的排水管在施工完毕后,均应通过严格的闭水试验进行检测;排水立管、干管等必须做严格的通球试验,确保符合要求时及时进行隐蔽工程手续验收工作。

加强隐蔽工程的质量控制

给排水系统的管材、管件以及设备的质量必须符合设计施工规定的要求,应认真检查管道是否畅通后,再确定进行施工,施工完毕后再复检管道是否畅通;隐蔽工程的给水管道必须严格通水检测,安装完毕后的给水管道依据相关规定标准要求采取加压试验进行检测。隐蔽之前依照图纸要求检查各方面是否遗漏,安装位置、操作方法等方面是否满足设计的规范要求,经过水压、闭水和灌水试验,并通过验收合格方可进行工程的隐蔽工作。

3.施工后期的管理

严格施工后的质量把控验收工作,做好工程信息资料的收集整理工作,并依照专门的验收规范和标准进行工程的验收,尤其要加强隐蔽工程、被检验项目的质量验收工作,及时发现问题,找出原由并按合理的程序加以处理,亦或采取各种措施和方法进行调整和整改,将各种问题隐患消灭在萌芽状态,待各项整改措施验收合格后才能进入后续工序或分项施工。只有各项检测和验收符合规定的标准后,方可进行分部、分项工程的验收工作。在未进行工程竣工的验收移交前,要加强工程资料的收集和整理工作,以确保给排水工程的合理运行和管理。

4.结语

给排水工程必须严格依照国家技术标准的具体要求,确保完全符合相关的施工质量验收规范。为了满足于理想的施工管理水平,应严格组织设计施工管理,加强各工序和各环节的工序质量控制,重点突出施工管理中的难点进行改进和革新,并不断完善施工的质量管理措施,以确保给排水工程的整体施工质量。

【参考文献】

[1]熊湘捷.浅析给排水工程存在问题及控制措施[J].福建建材,2007,(06).

[2]刘洋,宋德全.浅谈建筑给排水施工中的安全和质量管理[J].中国新技术新产品,2009,(04).

[3]葛贤平.浅议建筑给排水施工质量的保证措施[J].中国新技术新产品,2009,(06).

1. 高层建筑给排水论文

2. 工程项目管理论文参考范文

3. 浅谈智能建筑相关论文

4. 浅谈工程项目管理论文

5. 浅析工程技术管理论文

6. 高层建筑施工管理论文

328 评论

喊我11就很好

要:近些年来,建筑给排水的最大热点是新型管材的广泛应用。传统的镀锌钢管和普通排水铸铁管由于易锈蚀、自重大、运输施工不便等原因被取而代之。目前, 建筑给排水常用管材主要有塑料管,金属管和复合管三种。现在就常用管材的一些特性,优缺点,使用范围做一简要论述。关键词:建筑给排水 管材 塑料管 金属管 复合管1.塑料管塑料管是合成树脂加添加剂经熔融成型加工而成的制品。添加剂有增塑剂,稳定剂,填充剂,润滑剂,着色剂,紫外线吸收剂,改性剂等。常用塑料管有:硬聚氯乙烯管(PVC-U),高密度聚乙烯管(PE-HD), 交联聚乙烯管(PE-X),无规共聚聚丙烯管(PP-R),聚丁烯管(PB),工程塑料丙烯晴-丁二烯-苯乙烯共聚物(ABS)等。塑料管的原料组成决定了塑料管的特性。塑料管的主要优点:(1).化学稳定性好,不受环境因素和管道内介质组分的影响,耐腐蚀性好。(2).导热系数小,热传导率低,绝热保温,节能效果好。(3).水力性能好,管道内壁光滑,阻力系数小,不易积垢,管内流通面积不随时间发生变化,管道阻塞机率小。(4).相对于金属管材,密度小,材质轻,运输,安装方便,灵活,简捷,维修容易。(5).可自然弯曲或具有冷弯性能,可采用盘管供货方式,减少管接头数量。其主要缺点:(1).力学性能差,抗冲击性不佳,刚性差,平直性也差,因而管卡及吊架设置密度高。(2).阻燃性差,大多数塑料制品可燃,且燃烧时热分解,会释放出有毒气体和烟雾。(3).热膨胀系数大,伸缩补偿必须十分强调。所以,在推广塑料管的同时,还需要发展技术克服其缺点。 塑料管性能 物理性能:塑料管的物理性能和铝塑复合管,钢管,铜管比较见表1:表1物理性能 单位 PVC-U PE PE-X PP PB ABS 钢 铜 密度 g/cm 导热系数 w/mk 50 400 热膨胀系数 mm/m°C 弹性模量 MPa 3000 600 600 210000 110000 拉伸强度 MPa 40 25 >25 28 17 40 700 150 硬度 R 120 70 100 60 230HB 使用温度 °C 0-60 -60-60 -60-95 -20-95 -20-95 -20-80塑料管的物理性能影响管道的方式,用途,补偿措施和管道保温等方面。如:(1).PVC-U、PP、ABS的力学性能相对较高, 被视为“刚性管”,明装较好。反之,PE、PE-X、PB作为“柔性管”适合暗敷。(2).塑料管的使用温度及耐热性能决定了PVC-U,PE,ABS仅能用于冷水管,而PE-X,PP, PB则可作为热水管。当建筑物有热水供应系统且冷热水采用统一管材时耐热性能成为主要指标。(3).塑料管因热膨胀系数高,在塑料管路中尤其是作为热水管,采用柔性接口,伸缩节或各种弯位等热补偿措施较多。其中以PE,PP等聚烯烃类为最。施工安装时如果对此没有足够重视,并采取相应技术措施,极易发生接口处因伸缩节而拉脱的问题。(4).由于导热系数低,塑料管的绝热保温性能优良进而可减少保温层的厚度甚至无需保温。当不同塑料管之间绝热性的比较除导热系数外,还同它们各自的管壁厚度有关。 承压性能:承压性能所涉及的内容是在一定条件下塑料管材能够承受的内压力和恒压下的破坏时间。从而确定与之有关的设计参数以及对管材的质量进行评价和监控。一般进行两项试验:液压试验和长期高温液压试验。 各种管材的承压性能见表2表2管 材 工作压力/MPa 试样试验压力/MPa 接头密封试验/MPa 爆破压力/MPa UPVC 42/h De≤90,4.2PNDe>90,3.36PN PEX ℃常温 ABS 4~8 PB 1.6~2.5/冷水热水 PP-RPP-C 常温℃ 20℃,11h,16MPa80℃,48h,℃,170h, HDPE 热水冷水 卫生性能:理化卫生指标。其中PE,PE-X,PP,PB和ABS易达标。而PVC-U管材在生产时应使用无毒PVC树脂和卫生及稳定剂才能满足卫生性能的要求。 给水塑料管的应用结构形式单一,材料品种众多且性能各异.常用给水塑料管的特点列表如下:表3品种 优 点 缺 点 连接方式 PVC-U 抗腐蚀力强,易于粘合,价廉,质地坚硬 有UPVC单体和添加剂渗出,不适用于热水输送;接头粘合技术要求高,固化时间较长 粘合、螺纹 HDPE 韧性好,较好的疲劳强度,耐温度性能较好;质轻,可挠性和抗冲性能好 熔接需要电力;机械连接,连接件大 挤压夹紧、热熔合、电熔合 PEX 耐温性能好,抗蠕变性能好 只能用金属件连接;不能回收重复利用 挤压夹紧 PB 耐温性能好,良好的抗拉、压强度,耐冲击,低蠕变,高柔韧性 国内还没有PB 树脂原料,依赖进口,价高 挤压夹紧、热熔合、电熔合 PP-R 耐温性好 在同等压力和介质温度的条件下,管壁最厚 热熔合 ABS 强度大,耐冲击 耐紫外线差,粘接固化时间较长 粘合、螺纹、电熔合一般情况聚氯乙烯管由于价格低廉,在不考虑水质影响,在冷水供水系统属于首选管材,而当温度较高时,可选用聚乙烯管或交联聚乙烯管、聚丙烯管、聚丁烯管。 排水塑料管的应用材质单一:硬聚氯乙烯结构形式多样:芯层发泡管,空壁管,螺旋管,芯层发泡螺旋管,空壁螺旋管。其存在的一些问题:(1).热膨胀系数大,需设置伸缩补偿装置来解决。(2).刚度小,平直性差,需加密管卡、支架、吊架来解决。(3).耐热性差,软化温度低,需限制排水温度,限制使用场所和控制与热源的距离来解决。(4).阻燃性差,在穿越楼板、上人屋面的屋面板、防火墙、管道井井壁处需设置阻火圈和防火套管来解决。(5)抗机械冲击性差,需强化施工技术,精心施工来解决。(6)隔声性差,塑料管的噪声大于铸铁管,管道明装且管道位置靠近卧室时,问题尤为突出。降噪的方式,提高管道材质的隔声效果,芯层发泡管空壁管是基于这一思路而开发的;降噪的另一方式是改变水流条件,螺旋管是基于这一思路而开发的。将两种方式结合起来的思路是芯层发泡螺旋管和空壁螺旋管的开发。相同条件下,不同结构形式的排水塑料管,其噪声测定结果:普通管>芯层发泡管>空壁管>螺旋管排水塑料管的应用是在取代普通排水铸铁管的工作上进行的。目前,排水塑料管已可在建筑高度为100m以下的建筑物内使用,但各地区的进展很不平衡。当建筑高度大于、等于100m的高层建筑和不适宜采用排水塑料管的场合,可采用柔性抗震排水铸铁管。[next] 2.金属管 镀锌钢管镀锌钢管的被取代既不意味金属管被取代,也不意味镀锌钢管在整个建筑给水领域被取代。镀锌钢管由于价格低廉、性能优越,防火性能好,使用寿命长等优点,还将在消防给水系统,尤其是自动喷水灭火系统中应用.而塑料管(承压小)则不应在消防给水系统和生活-消防,生产-消防共有系统中应用。 铜管金属管中最具优势的是铜管,铜管应用较久,优点较多,管材和管件齐全,接口方式多样,较多的应用在热水管路中,目前存在的主要问题在于铜的折出量容易超标。 铸铁管给水铸铁管与钢管相比有不易腐蚀、造价低、耐久性好等优点,适合于埋地敷设。缺点是质脆、重量大、长度小等。连接方式一般采用承插连接。卡箍式铸铁排水管是一种新型的建筑用排水管材,60年代开始进入国际市场,经过几十年的推广和应用,这种管材已得到国际上的普遍认可。这种管材与传统的承插式铸铁排水管道相比有许多优点,是一种更新换代产品,但由于这种管材及配件价格相对较贵,所以在国内一直未能得到普及推广。 其它:不锈钢管也受到工程技术人员的青睐,有关方面正从减少壁厚,降低价格方面着手,以利于推广。铝合金管是铝厂向给排水行业推出的新品种。镀镍钢管是和镀锌钢管性质最近,而耐腐蚀性能远远超过镀锌钢管的新颖管材,在解决了降低镀层费用和管材断口处施工现场上镍工艺后,有望在一定范围内得到采用。涂塑钢管则是在金属管材中前景看好的一种管材,且管道布置和敷设、接口方式和施工安装均与镀锌钢管相同,是这种管材最容易被接受。由于其涂层薄、价格低,也最容易被推广。3.复合管:复合管包括衬铅管、衬胶管、玻璃钢管。复合管大多是由工作层(要求耐水腐蚀)、支承层、保护层(要求耐腐蚀)组成。复合管一般以金属作支撑材料,内衬以环氧树脂和水泥为主, 它的特点是重量轻、内壁光滑、阻力小、耐腐性能好;也有以高强软金属作支撑,而非金属管在内外两侧,如铝塑复合管,它的特点是管道内壁不会腐蚀结垢,保证水质;也有金属管在内侧,而非金属管在外侧,如塑覆铜管,这是利用塑料的导热性差起绝热保温和保护作用。根据金属的材料可分为:(1).钢塑复合管(2).不锈钢-塑复合管,塑覆不锈钢管(3).塑覆铜管(4).铝塑复合管,交联铝塑复合管(5)衬塑铝合金管应该说复合管材是管径≥300mm以上给排水管道最理想的管材。它兼有金属管材强度大,刚性好和非金属管材耐腐蚀的优点。但它又是目前发展较缓慢的一种管材。这是因为:(1).两种管材组合在一起比单一管材价格偏高。(2).两种材质热膨胀系数相差较大,如粘合不牢固而环境温度和介质温度变化又较剧烈,容易脱开,而导致质量下降。复合管的连接宜采用冷加工方式,热加工方式容易造成内衬塑料的伸缩、变形乃至熔化。一般有螺纹、卡套、卡箍等连接方式。由于复合管尚属新型管材,我国还未有统一的设计、施工及验收规范。设计及施工人员往往套用镀锌管的工艺来进行设计与施工,故在此不作一一赘述。

210 评论

相关问答

  • 建筑给水排水设计论文

    给排水工程对城市发展建设有着重要意义,因为给排水会影响到城市居民正常生活和社会稳定。下面是我为大家整理的给排水相关论文,供大家参考。 【摘要】看一个城市是否发达

    好吃鬼玲 2人参与回答 2023-12-08
  • 给排水建筑材料论文

    要:近些年来,建筑给排水的最大热点是新型管材的广泛应用。传统的镀锌钢管和普通排水铸铁管由于易锈蚀、自重大、运输施工不便等原因被取而代之。目前, 建筑给排水常用管

    毛头猴子 3人参与回答 2023-12-07
  • 建筑给排水论文3000

    要:近些年来,建筑给排水的最大热点是新型管材的广泛应用。传统的镀锌钢管和普通排水铸铁管由于易锈蚀、自重大、运输施工不便等原因被取而代之。目前, 建筑给排水常用管

    freekalong 3人参与回答 2023-12-12
  • 建筑给水排水毕业论文

    该专业的论文主要涉及建筑给排水及水处理两方面的内容,一般有设计类论文和实验类论文,筑龙网上可以找到相关资料

    Lisa要去旅行 3人参与回答 2023-12-11
  • 建筑给水排水核心期刊

    08版目录1.岩土工程学报 2.建筑结构学报 3.土木工程学报 4.岩石力学与工程学报 5.建筑结构 6.工业建筑 7.哈尔滨建筑大学学报 8.中国给水排水 9

    bamanai119 8人参与回答 2023-12-08