• 回答数

    2

  • 浏览数

    97

小优雅0811
首页 > 学术期刊 > 锅炉房设计论文参考文献

2个回答 默认排序
  • 默认排序
  • 按时间排序

蝶澈kaixin

已采纳

2 accident reason analysis Analysis of gas boiler room the cause of the accident, there are two possible: boiler ontology explosion, boiler room to explode gas explosion concentration and explosions. Boiler blast furnace body, because be in, or flue gas mixture in explosive existence, when achieved by fire or explosion limit, boiler heat ignites causing accidents in itself. This point and the national norm of building fire system that conform to the relevant provisions. The actual current boiler product has considered safe production measures to avoid it. Qualified gas boiler itself has the explosion-proof process design, such as burner in abnormal situation automatic stop, self-control device also stop output fuel, Gas boiler combustion system higher automatization, including the gas pressure is high, low limit alarm protection, when the control logic where step does not meet the conditions set start corresponding interlock protection. Avoid the boiler exploded possibility, but still ontology exist above another possibility, can avoid? How to avoid it? Three measures In fact in design, according to the boiler design code "and" automatic fire alarm system design code "GB50116-1998 etc standard, we have taken the following measures: Natural gas pipelines valves, meter, may occur gas leak place, boiler room may produce gas storage product area [relative density 0.8, it is to be in commonly roof area in these areas], all equipped with combustible gas concentration measurement alarm device, according to combustible gas concentration situation give out sound and light alarm signal and start exhaust fan, when leakage accident concentrations reach explosion limit of the lower limit 50% [this value for reference only], but also immediately close natural air intake duct total intake solenoid valves. In the boiler room and a natural gas pipeline in and out of the room, the incident, but also with the smoke exhaust fan combustible gas alarm interlocking (start). Electrical, instrument by cable selection TongXin, not less than 1.5 mm2 minimum section. Gas radiation tube tube top or the nearby, the lightning rod should be installed above the pipe jacking tip should be not less than 3m, and its scope of protection tube top above not less than 1-m. Gas pipeline should be static grounding device that, when pipeline as metal materials, and lightning protection or electrical engineering protective grounding wire connected, the measured resistance R more than 4 Ω. In pipe joints, such as the bend, flange, valve and pipe with good place cannot metal contact, also with metal soft line will be both ends jumper. In the boiler room and a natural gas pipeline in and out of the room door, window take pressure measures. According to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area: devin in item 3, in the process of production use fire equipment near, A combination of these several measures can clearly, electrical equipment selection for the explosion. At the same time according to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area devin: the first 2 items, and the highest possible flammable explosive chroma does not exceed 10% of the lower limit, Close air intake duct natural total intake solenoid valves, concentration exceed 10% of the lower limit explosion limit, boiler room near the roof area are gas storage product area, so lighting lamps and lanterns and switch choosing is explosion-proof type. 4 conclusion In gas boiler room electrical design, lighting choose explosion-proof lamps, other part adopts the explosion-proof type. references [1] boiler design standard. GB50041-1992. [2] explosion and fire dangerous environment electrical device design standard. GB50058-1992. [3] the code for fire protection design of buildings. GB50016-2006. [4] automatic fire alarm system design standard. GB50116-1998.

139 评论

Ashtray喵

GB50041-92锅炉房设计规范适用于工业、民用、区域锅炉房和室外热力管道设计。施行于一九九三年七月一日起,参考文献为《锅炉房设计规范》。

271 评论

相关问答

  • 锅炉论文网

    写毕业论文用的吧,这要看你的专业方向了,偏向设计的话,不妨搜集一些国内外新型锅炉发展方向和现状的资料,加上自己的想法就是一篇很不错的论文,比如时下新兴的CFB锅

    A田欣团队 3人参与回答 2023-12-08
  • 煤矿锅炉房毕业论文

    1.在毕业论文锅炉输煤中期检查报告中,应简述锅炉输煤的基本情况,包括锅炉的型号、设计规格、使用状况等;2.分析现场输煤工况情况,对煤投入量、煤粉流量、煤粉细度、

    会逃跑的桃子 2人参与回答 2023-12-09
  • 锅炉论文的参考文献

    摘要: 高炉煤气的利用方式很多,目前我国最主要的利用方式是高炉煤气发电项目(包括燃烧高炉煤气和高炉煤气、煤粉混烧)。分析燃煤锅炉掺烧高炉煤气和全烧高炉煤气后的工

    无敌小猪猪侠 2人参与回答 2023-12-11
  • 锅炉房设计论文参考文献

    2 accident reason analysis Analysis of gas boiler room the cause of the accident

    小优雅0811 2人参与回答 2023-12-07
  • 锅炉论文

    火力发电厂锅炉节能降耗策略探讨论文 摘要:火力发电厂锅炉是耗能大户,做好节能降耗能够有效缓解我国资源紧缺现象,并降低企业生产成本,提高发电厂经济效益。本文通过概