• 回答数

    7

  • 浏览数

    175

李晓诗125
首页 > 职称论文 > 电气英文原文论文文献

7个回答 默认排序
  • 默认排序
  • 按时间排序

冷月无痕MNG

已采纳

你去知节网上找些,很多的,也很专业的!

235 评论

miss.w\^O^/

Electric Automation 电气自动化ELECTRIC AUTOMATION DEVICE AND METHOD FOR ADJUSTING THE FUNCTIONS OF THE ELECTRIC AUTOMATION DEVICE The invention relates to an electric automation device comprising a control unit that is controlled by a computer. In order to create an automation device that can be set to predefined functions in a particularly flexible manner while requiring less testing, a computer hardware component (2) is provided with control software comprising a basic functional area which includes an operating system (3), a device driver (4), and communication modules (5) so as to form a basic automation device (1) while the basic automation device (1) is complemented with any application modules (7a, 7b, 7c, 8, 9) that can be connected to the basic functional area via a software interface (6) in order to obtain the automation device. The invention also relates to a method for producing or adjusting the functions of such an electric automation device. 电气自动化专业介绍一、专业概况 随着高新技术的发展和生产自动化程度的提高,我国国民经济发展,正在和继续需要大批技术应用型实用人才。电气自动化技术是现代制造技术中不可缺少的重要技术门类,也是一个国家科技实力乃至综合竞争力的综合反映,在工业发展中具有前导地位。电气自动化技术,集机、电、计算机、信息处理等多学科于一体,是多学科相互交叉、渗透、结系淖酆涎Э疲�诠�窬�媒ㄉ柚姓加兄匾�牡匚弧R虼耍�梢运档缙�远��际跏嵌ヌ炝⒌氐氖乱担�枪�窬�梅⒄购腿嗣裆�钏�教岣叩奈镏侍跫�� ?br> (一)、培养目标本专业培养德、智、体、美、劳全面发展,具有良好职业道德和综合业务素质,具备较强的创新意识和创业能力,掌握电气自动化技术、计算机控制技术的基础理论,能在生产、建设、管理、服务第一线从事常用电气自动化设备、常用电气设备、供配电系统和装置、计算机控制系统、PLC控制系统的安装、调试、运行和维护的实用型高技能专门人才。 (二)、培养要求及职业能力分析 1、培养要求:本专业主要学习电气自动化的专业技术知识,应具有较强的本专业技术应用能力。 2、职业能力分析 (1)具有良好的身体素质、职业道德和人文素质,较强的语言文字表达能力和一定的社会交往能力及继续学习能力。 (2)具有较强的用英语进行人际和人机交流能力,具有阅读和翻译本专业有关英文资料的能力。 (3)具有较强的在信息化社会中工作、学习、生活所必备的计算机应用能力;熟练使用电子电气CAD软件;掌握一门程序设计语言。 (4)具有分析和测试常见的电工电子线路,能设计一般电工电子应用线路,能熟练使用常规电工电子仪器、仪表,具有熟练的电工基本操作技能。 (5)熟悉常用低压电器的基本原理及使用;能熟练阅读电气控制线路的原理图与接线图;具有对常规电气设备、供配电设备等电气控制系统进行安装、调试、维护能力。 (6)具有正确选用、安装、调试、维护电力电子装置和典型交、直流调速系统的能力。 (7)具有熟练的可编程控制器应用能力。 (8)具有以嵌入式计算机数字控制技术为核心的新技术基本应用能力,对相应控制系统具有调试维护能力。 (9)具有对一般的机械零件图、产品装配图与机械、液压和气压传动系统回路的识读能力,了解常用机械设备的结构特点及工艺过程,了解常见的机械和电气的配合关系。 (10)了解企业管理的基本知识,具有一定的质量意识。 (三)、课程设置 课程设置共分五部分:公共必修课、专业必修课、专业限定选修课、专业选修课及公共选修课。 1、公共必修课包括:思想道德修养、法律基础、邓小平理论、马克思主义哲学、体育、英语、高等数学、计算机操作基础等。 2、专业必修课包括:电工基础、模拟电子技术、数字电子技术、电机及拖动基础、机械制图及公差、机械工程基础、嵌入式计算机原理及应用、C语言程序设计、自动检测与转换技术、现代电力电子技术、可编程序控制器应用、自动控制原理与系统、C语言、工厂电气控制技术、电子电气CAD、变配电技术、变频调速原理与应用、工业控制网络、DSP原理与应用及专业英语等。其中主干课程为:电工基础、模拟电子技术、数字电子技术、电机及拖动基础、嵌入式计算机原理及应用、自动检测与转换技术、现代电力电子技术、可编程序控制器应用、自动控制原理与系统等。 3、专业限选课包括:计算机控制技术、工业自动化仪表、控制电机、智能控制等。 4专业任选课包括:电工电子工艺、多媒体技术、楼宇自动化、计算机系统仿真、计算机维修、程序设计(VB)等。 5、公共选修课包括:包括两个能力模块:经济管理科学类和人文与社会科学类。 (四)、实践教学环节 1、专业主要实践教学包括:电工实验、模拟电子技术实验、数字电子技术实验、电机与电力拖动实验、可编程序控制器应用实验、嵌入式计算机原理实验、现代电力电子技术实验、电工基础课程设计、电子技术课程设计、嵌入式计算机原理课程设计、可编程序控制器应用课程设计、自控系统课程设计、综合系统实训、金工实习、电工电子实习、专业参观、综合生产实习、毕业设计等。 2、非专业实践教学包括:入学教育、军训、暑期社会实践、社团活动、体育活动、文艺活动等。 (五)、职业技能证书 本专业证书包含三个方面: 1、公共必修证书:PET、计算机一级证书。 2、专业必修证书:CAD初级、维修电工中级。 3、任选证书:CET四级证书、计算机三级证书(单片机方向)、CAD中级证书、维修电工高级证书、气液电控制技术。 (六)、本专业师资力量 学院拥有一支学术造诣高、教学经验丰富、实践能力强的师资队伍。电气自动化技术专业现有师资26人,其中副高职称以上有17人,“双师型”教师10人。能够满足公共基础课、专业基础课和专业课的理论及实践教学的需要。 二、职业前景 1、对口行业 电气自动化技术是传统而具有新内涵的专业,本专业培养拥护党的基本路线,德、智、体、美等全面发展,具备从事电气自动化技术所需要的理论知识和职业技术能力,主要在生产、建设、服务和管理等第一线工作的高级技术应用性专门人才。本专业的毕业生可就职于国防、航天、航空、航海、铁道、机械、轻工、化工、电子、电力、电信、钢铁、石油、矿山、煤炭、地质、勘测等广泛的工业、农业、科学研究领域,也可就职于现代物流及现代服务业。 2、就业前景 在上海市经济委员会的《上海制造业战略升级的行动纲要》中指出:加快推动制造业的战略升级是贯彻党的十六大精神,坚定地走新型工业化道路,实现向制造业强国转变的国家战略需要,也是上海建立新型产业体系,提高城市综合竞争力,坚持“四个中心”的客观要求。上海制造业战略升级的重点包括:高新技术产业重点发展电子信息和现代生物与现代医药制造业;交通运输设备制造业重点发展汽车、轨道交通、船舶、民用飞机;装备制造业重点发展大型成套设备、电站设备、新能源和新型环保设备制造业;原材料制造业重点发展石油化工和精细化工、精品钢材制造业;生产性服务业重点发展制造业物流、技术服务等产业;大力发展就业广、清洁型的都市型工业。根据电气自动化的内涵,上述产业无不包含电气自动化技术,同时也对电气自动化技术专业的人才提出了更高的要求。据上海市政府组织的《面向新世纪上海紧缺人才需求趋势与开发研究对策》的报告显示,复合型技术人才是紧缺的专业人才,而电气自动化技术专业是培养复合型技术人才的有效载体。可以预见在未来数年内,电气自动化专业毕业生就业前景良好。

310 评论

吃撑了别跑

用于分布式在线UPS中的并联逆变器的一种无线控制器A Wireless Controller for Parallel Inverters in Distributed Online UPS SystemsJosep M. Guerrero', Luis Garcia de Vicufia", Jose Matas'*, Jaume Miret", and Miguel Castilla". Departament #Enginyeria de Sistemes, Automatica i Informhtica Industrial. Universitat Polithica de CatalunyaC. Comte d'Urgell, -Barcelona. Spain. Email: .. Departament #Enginyeria Electrbnica. Universitat Polit6cnica de CatalunyaAV. Victor BaLguer s/n. 08800I - Vilanova i la Geltrh. SpainAbsiract - In this paper, a novel controller for parallelconnectedonline-UPS inverters without control wireinterconnections is presented. The wireless control technique isbased on the well-known droop method, which consists inintroducing P-oand Q-V schemes into the inverters, in order toshare properly the power drawn to the loads. The droop methodhas been widely used in applications of load sharing betweendifferent parallel-connected inverters. However, this methodhas several drawbacks that limited its application, such as atrade-off between output-voltage regulation and power sharingaccuracy, slow transient response, and frequency and phasedeviation. This last disadvantage makes impracticable themethod in online-UPS systems, since in this case every modulemust be in phase with the utility ac mains. To overcome theselimitations, we propose a novel control scheme, endowing to theparalleled-UPS system a proper transient response, strictlyfrequency and phase synchronization with the ac mains, andexcellent power sharing. Simulation and experimental resultsare reported confirming the validity of the proposed . INTRODUCTIONThe parallel operation of distributed Uninterruptible PowerSupplies (UPS) is presented as a suitable solution to supplycritical and sensitive loads, when high reliability and poweravailability are required. In the last years, many controlschemes for parallel-connected inverters has been raised,which are derived from parallel-schemes of dc-dc converters[I], such as the master-slave control [2], or the democraticcontrol [3]. In contrast, novel control schemes have beenappeared recently, such as the chain-structure control [4], orthe distributed control [ 5 ] . However, all these schemes needcontrol interconnections between modules and, hence, thereliability of the system is reduced since they can be a sourceof noise and failures. Moreover, these communication wireslimited the physical situation ofthe modules [6].In this sense, several control techniques has been proposedwithout control interconnections, such as the droop this method, the control loop achieves good power sharingmaking tight adjustments over the output voltage frequencyand amplitude of the inverter, with the objective tocompensate the active and reactive power unbalances [7].This concept is derived from the power system theory, inwhich the frequency of a generator drops when the powerdrawn to the utility line increases [8].0-7803-7906-3/03/$ 02003 IEEE. 1637However, this control approach has an inherent trade-offbetween voltage regulation and power sharing. In addition,this method exhibits slow dynamic-response, since it requireslow-pass filters to calculate the average value of the activeand reactive power. Hence, the stability and the dynamics ofthe whole system are hardly influenced by the characteristicsof these filters and by the value of the droop coefficients,which are bounded by the maximum allowed deviations ofthe output voltage amplitude and , when active power increases, the droopcharacteristic causes a frequency deviation from the nominalvalue and, consequently, it results in a variable phasedifference between the mains and the inverter output fact can be a problem when the bypass switch mustconnect the utility line directly to the critical bus in stead ofits phase difference. In [9], two possibilities are presented inorder to achieve phase synchronization for parallel lineinteractiveUPS systems. The first one is to locate a particularmodule near the bypass switch, which must to synchronizethe output voltage to the mains while supporting overloadcondition before switch on. The second possibility is to waitfor the instant when phase matching is produced to connectthe , the mentioned two folds cannot be applied to aparallel online-UPS system, since maximum transfer timeought to be less than a % of line period, and all the modulesmust be always synchronized with the mains when it ispresent. Hence, the modules should be prepared to transferdirectly the energy from the mains to the critical bus in caseof overload or failure [lo].In our previous works [11][12], we proposed differentcontrol schemes to overcome several limitations of theconventional droop method. However, these controllers bythemselves are inappropriate to apply to a parallel online-UPS system. In this paper, a novel wireless control scheme isproposed to parallel different online UPS modules with highperformance and restricted requirements. The controllerprovides: 1) proper transient response; 2) power sharingaccuracy; 3) stable frequency operation; and 4) good phasematching between the output-voltage and the utility , this new approach is especially suitable for paralleled-UPS systems with true redundancy, high reliability andpower availability. Simulation and experimental results arereported, confirming the validity of this control . 1. Equivalenl cimuif ofan invener connecled 10 a bust"Fig. 2. P-odraop . REVlEW OF THE CONVENTIONAL DROOP METHODFig. 1 shows the equivalent circuit of an inverter connectedto a common bus through coupled impedance. When thisimpedance is inductive, the active and reactive powers drawnto the load can be expressed asEVcosQ - V2 Q=where Xis the output reactance of an inverter; Q is the phaseangle between the output voltage of the inverter and thevoltage of the common bus; E and V are the amplitude of theoutput voltage of the inverter and the bus voltage, the above equations it can be derived that the activepower P is predominately dependent on the power angle Q,while the reactive power Q mostly depends on the outputvoltageamplitude. Consequently, most of wireless-control ofparalleled-inverters uses the conventional droop method,which introduces the following droops in the amplitude Eand the frequency U of the inverter output voltageu = w -mP (3)E = E ' - n Q , (4)being W* and E' the output voltage frequency and amplitudeat no load, respectively; m and n are the droop coefficientsfor the frequency and amplitude, , a coupled inductance is needed between theinverter output and the critical bus that fixes the outputimpedance, in order to ensure a proper power flow. However,it is bulky and increase:; the size and the cost of the UPSmodules. In addition, tho output voltage is highly distortedwhen supplying nonlinezr loads since the output impedanceis a pure is well known that if droop coefficients are increased,then good power sharing is achieved at the expense ofdegrading the voltage regulation (see Fig. 2).The inherent trade-off of this scheme restricts thementioned coefficients, which can be a serious limitation interms of transient response, power sharing accuracy, andsystem the other hand, lo carry out the droop functions,expressed by (3) and (4), it is necessary to calculate theaverage value over one line-cycle of the output active andreactive instantaneous power. This can be implemented bymeans of low pass filters with a smaller bandwidth than thatof the closed-loop inverter. Consequently, the powercalculation filters and droop coefficients determine, to a largeextent, the dynamics and the stability of the paralleledinvertersystem [ conclusion, the droop method has several intrinsicproblems to be applied a wireless paralleled-system ofonline UPS, which can he summed-up as follows:Static trade-off between the output-voltage regulation(frequency and amplitude) and the power-sharingaccuracy (active an4d reactive).2) Limited transient response. The system dynamicsdepends on the power-calculation filter characteristics,the droop coefficients, and the output of ac mains synchronization. The frequency andphase deviations, due to the frequency droop, makeimpracticable this method to a parallel-connectedonline UPS system, in which every UPS should becontinuously synchronized to the public ac )3)111. PROPOSED CONTROL FOR PARALLEL ONLINE UPSINVERTERSIn this work, we will try to overcome the above limitationsand to synthesize a novel control strategy withoutcommunication wires that could be appropriate to highperformanceparalleled industrial UPS. The objective is toconnect online UPS inverters in parallel without usingcontrol interconnections. This kind of systems, also namedinverter-preferred, should be continuously synchronized tothe utility line. When an overload or an inverter failureoccurs, a static bypass switch may connect the input line tothe load, bypassing the inve:rter [14][15].Fig. 3 shows the general diagram of a distributed onlineUPS system. This system consists of two buses: the utilitybus, which is connected lo the public ac mains; and thesecure bus, connected to the distributed critical loads. Theinterface between these buses is based on a number of onlineUPS modules connected in parallel, which providescontinuously power to the: loads [16]. The UPS modulesinclude a rectifier, a set of batteries, an inverter, and a staticbypass ac mainsutility busI I Ij distributed loads !Fig. 3. Online distributed UPS /I 4(4Fig. 4. Operation modes of an online UPS.(a) Normal operation. (b) Bypass operation. (c) Mains failureThe main operation modes of a distributed online UPS1) Normal operation: The power flows to the load, fromthe utility through the distributed UPS ) Mains failure: When the public ac mains fails, theUPS inverters supply the power to the loads, from thebatteries, without operation: When an overload situation occurs,the bypass switch must connect the critical busdirectly to the ac mains, in order to guarantee thecontinuous supply of the loads, avoiding the damageof the UPS this reason, the output-voltage waveform should besynchronized to the mains, when this last is are listed below (see Fig. 5):3)Nevertheless, as we state before, the conventional droopmethod can not satisfy the need for synchronization with theutility, due to the frequency variation of the inverters, whichprovokes a phase obtain the required performance, we present a transientP-w droop without frequency-deviation in steady-state,proposed previously by OUT in [ 111w=o -mP (5)where is the active power signal without the dccomponent,which is done by. -I t -1sP= p ,( s + t - ' ) ( s + o , )being zthe time constant of the transient droop transient droop function ensures a stable frequencyregulation under steady-state conditions, and 'at the sametime, achieves active power balance by adjusting thefrequency of the modules during a load transient. Besides, toadjust the phase of the modules we propose an additionalsynchronizing loop, yieldingo=w'-m%k,A$, (7)where A$ is the phase difference between the inverter and themains; and k, is the proportional constant of the frequencyadjust. The steady-state frequency reference w* can beobtained by measuring the utility line second term of the previous equality trends to zero insteady state, leading tow = w' - k4($ -@'), (8)being $and $* the phase angles of the output voltage inverterand the utility mains, into account that w = d $ / d t , we can obtain thenext differential equation, which is stable fork, positived$ *dt dt- + km$ = - + k,$' . (9)Thus, when phase difference increases, frequency willdecrease slightly and, hence, all :he UPS modules will besynchronized with the utility, while sharing the power drawnto the . CONTROLLIEMRP LEMENTATIONFig. 5 depicts the block diagram of the proposedcontroller. The average active power P , without the dccomponent, can be obtained by means of multiplying theoutput voltage by the output current, and filtering the product........................................................................................io",.LSj'nchronirorion loop.......................................................................................Fig. 5. Block diagram of the proposed a band-pass filter. In a similar way, the averagereactive power is obtained, hut in this case the output-voltagemust be delayed 90 degrees, and using a low-pass order to adjust the output voltage frequency, equation(7) is implemented, which corresponds to the frequencymains drooped by two transient-terms: the transient activepower signal term; and the phase difference term, whichis added in order to synchronize the output voltage with theac mains, in a phase-locked loop (PLL) fashion. The outputvoltageamplitude is regulated by using the conventionaldroop method (4).Finally, the physical coupled inductance can be avoided byusing a virtual inductor [17]. This concept consists inemulated an inductance behavior, by drooping the outputvoltage proportionally to the time derivative of the outputcurrent. However, when supplying nonlinear loads, the highordercurrent-harmonics can increase too much the outputvoltageTHD. This can be easily solved by using a high-passfilter instead of a pure-derivative term of the output current,which is useful to share linear and nonlinear loads [I 1][12].Furthermore, the proper design of this output inductance canreduce, to a large extent, the unbalance line-impedanceimpact over the power sharing . SIMULATION AND EXPERIMENTARELS ULTSThe proposed control scheme, (4) and (7), was simulatedwith the parameters listed in Table 1 and the scheme shownin Fig. 6, for a two paralleled inverters system. Thecoefficients m, n, T, and kv were chosen to ensure stability,proper transient response and good phase matching. Fig. 7shows the waveforms of the frequency, circulating currents,phase difference between the modules and the utility line,and the evolution of the active and reactive powers. Note theexcellent synchronization between the modules and theACmiiinr 4 j. ...L...... ..........................B...u...n...... ................................... iFig. 6. Parallel operation oftwa online UPS modules,mains, and, at the same time, the good power sharingobtained. This characteristik let us to apply the controller tothe online UPS paralleled I-kVA UPS modules were built and tested in order toshow the validity of the proposed approach. Each UPSinverter consisted of a single-phase IGBT full-bridge with aswitching frequency of 20 kHz and an LC output filter, withthe following parameters: 1. = 1 mH, C = 20 WF, Vi" = 400V,v, = 220 V, I50 Hz. The controllers of these inverters werebased on three loops: an inner current-loop, an outer PIcontroller that ensures voltage regulation, and the loadsharingcontroller, based on (4) and (7). The last controllerwas implemented by means of a TMS320LF2407A, fixedpoint40 MHz digital sigrial processor (DSP) from TexasInstruments (see Fig. 8), using the parameters listed in TableI. The DSP-controller also includes a PLL block in order tosynchronize the inverter with the common bus. When thisoccurs, the static bypass switch is tumed on, and the droopbasedcontrol is 7 Wa\cfc)rms for , ;mnectcd in parallel. rpchrontred io Ihc ac mdnl.(a) Frequencics ufhoth UPS (b) Clrculattng currcni among modulcs. (CJ Phmc d!Nercn;: betucen ihc UPS a#>dth e ai mum(d) Ikiril uf the phze diNmncc (e) md (0 Activc and rcactlw pouerr "I ooih UPSNote that the iimc-acs arc deliheratcly JiNercni due in thc disiinct timuion*uni) ofthe \ THE PARALLELESDYS Order I IFilter Cut-off Frequency I 0, I 10 I ragsFig. 8 shows the output-current transient response of theUPS inverters. First, the two UPS are operating in parallelwithout load. Notice that a small reactive current is circlingbetween the modules, due to the measurement , a nonlinear load, with a crest factor of 3, is connectedsuddenly. This result shows the good dynamics and loadsharingof the paralleled system when sharing a . 8. Output current for the two paralleled UPS, during the connection of Bcommon nonlinear load with a crest factor of 3. (Axis-x: 20 mddiv. Axis-y:5 Mdiv.).VI. CONCLUSIONSIn this paper, a novel load-sharing controller for parallelconnectedonline UPS systems, was proposed. The controlleris based on the droop method, which avoids the use ofcontrol interconnections. In a sharp contrast with theconventional droop method, the controller presented is ableto keep the output-voltage frequency and phase strictlysynchronized with the utility ac mains, while maintaininggood load sharing for linear and nonlinear loads. This fact letus to extend the droop method to paralleled online the other hand, the proposed controller emulates aspecial kind of impedance, avoiding the use of a physicalcoupled inductance. results reported here show theeffectiveness of the proposed approach.

236 评论

Blackstar01234

[1] Corrêa, J., Farret F., Canha L.,et al. An electrochemical-based fuel-cell model suitable for electrical engineering automation approach [J]. IEEE Transactions on industrial electronics. 2004, 51(5): 1103-1112.[2] wider, J., Michalski P.,Wszo ek G. Laboratory support for the didactic process of engineering processes automation at the Faculty of Mechanical Engineering [J]. Journal of Achievements in Materials and Manufacturing Engineering. 2006, 15(1-2): 199-206.给你找了两篇算是沾边文献。第一篇是电气化顶级期刊IEEE文献,被引用过100多次。第二篇被引用过十次。应该适合楼主。如果需要全文可以发邮件到另本人利用业余时间在百度知道里免费给网友查专业文献,纯属业余爱好,发的文献无存稿,请无关人员勿骚扰。

188 评论

2012骏马飞驰

关注这个问题

219 评论

伯符仲謀

Fire FightingAlong with the our country economic development rapid development, the lives of the people level unceasing enhancement, the city uses to be day by day anxious, urges the building to face the direction is developing. This kind of high level civil construction repair needed materials and the way also more hasten the diversification, and along with uses electricity the load and coal gas consumption quantity enlarging, proposed to the fire auto-alarm system design is higher, a stricter request. In order to guarantee the people life and property the security, the fire auto-alarm system design has become in the high level civil construction design one of most important design contents. Presently based on the author fire of auto-alarm system design overseeing work in the high level civil building experience, proposed in present national related standard and standard unclear true detail shallow opinion, by for the colleagues to discuss and to point out , design basis The fire auto-alarm system design is a specialized very strong technology work, at the same time also has the very strong policy-type. Therefore, first should be clear about the following design basis: 1st, must grasp the architectural design fire protection standard, the system design standard, the equipment manufacture standard, the installment construction approval standard and the administration laws and regulations and so on five big aspects fire laws and regulations, and in practical understanding present country related standard and standard positive word: "Must", "be supposed", "to be suitable", "may" and the reverse side word: "Strictly prohibits", "should not", "not have", "not to be suitable" the , must aim at high level civil building function, use and the protection object fire protection rank, earnestly carries out the present national related standard and the standard, earnestly treats the public security fire prevention surveillance department the examination and approval , fire auto-alarm system equipment establishmentFire detector establishmentOpens wide either the seal or the stair hall should alone divide the search coverage, and each 2 ~ 3 establish a fire first room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against the front room which smoke stair hall comes in handy) and the aisle should distinguish alone to divide the search coverage, specially front the room and the lift well, the scattered stair hall and the aisle are interlinked, has time the fire haze to be easier to gather or to flow, is the personnel disperses which saves goal with the fire prevention, therefore should install the fire detector. Regarding common elevator in front of room although is not the personnel disperses , but this front room and the lift well are interlinked, has time the fire haze to be also easy to gather or to flow, suitably alone divides the search coverage and installs the fire detector. The electric cable shaft therefore is easy to form pulls out the smoke inflammation the channel; Has when the fire the fire intensity not easily extends along the electric cable burns, for this, "the high level civil construction design fire protection standard" and "the civil construction electricity design standard" separately proposes the detailed specific stipulation in the construction and in the electric wire or on the electric cable shaping. But considered implements specifically the difficulty and the present situation, the electric cable shaft installs the fire detector is extremely essential, and coordinates the shaft the fire protection separation request, each 2 ~ 3 or each level elevator machine room should install the fire detector, its elevator is the important vertical transportation vehicle; Its two elevator machine room has has the fire risk; Its three lift well existence essential opens the hole, like the level gate opens between the hole, the air vent, the between permanence opens the hole with the elevator machine room or the pulley and so on; Its four when has the fire, the lift well often becomes the fire intensity spread the channel, is easy to threaten the elevator machine room the facility. Therefore, the elevator machine room establishes the fire detector is necessary, crown of also suitable establishment fire detector lift , the manual fire reports to the police the button establishment(Including guards against in front of smoke stair hall in view of various floors front room in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, should report to the police the button first choice spot as the establishment manual fire. In addition, the room also should establish the manual fire to the common elevator in front of to report to the police the the public active place (including hall, hall, dining room, multi-purpose hall and so on) and the main thoroughfare and so on place, the personnel very is all centralized, and mainly disperses the channel. Therefore should report to the police the button in these public active places main access establishment manual fires; The manual fire establishes which in the main thoroughfare reports to the police the button to guarantee "to a manual fire which most is close to reports to the police the button distance from a fire protection district any position not to be supposed to be bigger than 30 meters".3rd, the fire emergency broadcasts the speaker the establishmentThe aisle, the hall, the dining room and so on the public place personnel very are all centralized, and mainly disperses the channel. Therefore should press in these public places "to a recent speaker distance is not bigger than 25 meters from a fire protection district any spot" and "in the aisle last should not be bigger than meters the speaker to the aisle terminal distance" the establishment fire emergency to broadcast the speaker; Next also should establish the fire in the public bathroom place emergency to broadcast the first room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, also has the fire door separation and the sounds of people is confused and noisy, therefore should establish the fire emergency to broadcast the speaker. In front of the common elevator the room also should establish the fire emergency to broadcast the speaker. Disperses the stair hall also is has when the fire the personnel to disperse which saves goal with the fire prevention, also the sounds of people are confused and noisy, therefore should establish the fire emergency to broadcast the speaker, by favors the fire emergency broadcast to disperse the , fire alarm installment establishmentThe establishment fire emergency broadcast fire auto-alarm system, the author thought also should install the fire alarm installment, but its control procedure should be: The alarm apparatus should confirm after the fire, uses manual or the automatic control mode unification to the fire correlation region transmission warning, stops the alarm apparatus work in the stipulation time, the rapid linkage fire emergency broadcast and broadcasts to the people disperses the fire alarm installment establishment position, the author thought should report to the police the button position with the manual fire to be same, its wall surface installment should for be apart from the ground meters highly5th, fire special use telephone establishmentInstalls the fire special use telephone extension telephone, should be located the engine room which related also some people is on duty frequently with the fire linkage control (including fire water plant, spare electricity generation engine room, matches substation, mainly ventilates with air conditioning engine room, discharges fume engine room, fire prevention elevator machine room and other), the fire fighting control system operates the equipment place or the control room, the fire duty officers observation room, the security manages spot and so on public room. Sedan of theater box the fire elevator and in the ordinary elevator all should suppose the special use telephone, requests the elevator machine room and the elevator sedan theater box, the elevator machine room and the fire control room, the elevator sedan theater box and the fire control room and so on three compositions is reliable to speaks the correspondence telephone system. Usually in fire control room; The establishment elevator monitoring demonstration plate (including position indicator, direction indicating lamp, to speaks correspondence telephone, trouble lamp and so on), in order to carries on the necessity to the elevator running status which in the surveillance and the emergency case equipped with the manual fire to report to the police position and so on button, fire hydrant button also should install the fire special use telephone , fire linkage control 1st, the fire linkage control should include the control fire pump to open, to stop, also should demonstrate opens pumps the button the position and the fire pump work and the malfunction. When the fire hydrant is equipped with the fire hydrant button, its electric installation work spot also should demonstrate the fire pump the working mode active status (namely establishment fire pump work indicating lamp). 2nd, the fire linkage control should include the control spraying of water and the water atomization fire fighting system opens, stops, also should demonstrate the fire pump the work and the malfunction and the fluent display, reports to the police the valve, the safety signal valve working mode active status. In addition, to the basin, the water tank water level also should carry on the demonstration monitor; In order to prevent the overhaul signal valve is shut down, the author thought should use the belt electric signal the control signal valve by to demonstrate it opens the condition. 3rd, the fire linkage control other controls and the demonstration function, should carry out the present national related standard and the standard specific , fire auto-alarm system wiringIn order to prevent the fire occurs when the fire control, the correspondence and the warning line severance, causes the fire fighting work to be unable to carry on, creates the bigger economic loss; Also for the suppression electronmagetic interference (for example transformer, electric motor, electric cable and so on) the influence which produces to the fire auto-alarm system. The fire auto-alarm system transmission line and the fire control, the correspondence and the warning line should use the being flame-resistant electric cable, and should use the metal tube or the enclosed metal trunking protection. The fire manual positive governing installment line should use the fireproof electric cable, its electric cable also should use the metal tube or the enclosed metal trunking protection. Uses Ming Fushi, should takes the fire protection protective measures on the metal tube or the enclosed metal , concluding remarkThe author rests on the concrete project to implement the experience, elaborated the design basis, fire auto-alarm design actual problem and so on system equipment establishment, fire linkage control and its wiring pulls out some shallow opinions, its goal is enhances the fire auto-alarm system the design quality, discovered early and the notification fire, prevented and reduces the fire to harm, by protects the person and the property safety.消防 随着我国经济发展快速发展,人民生活的水平不断提高,城市使用是每天着急,敦促建设面临着发展的方向。这种高层次的民间建筑维修所需的材料和方式也更加多样化加快,而且随着使用电力负荷和煤气消费量扩大,提议消防自动报警系统设计较高,更严格的要求。为了保证人民生命和财产的安全,消防自动报警系统的设计已经成为在高级别民间建筑设计的一个最重要的设计内容。目前的基础上撰文火灾自动报警系统设计监督工作的高层次的民间建设的经验,建议在目前国家相关标准和标准不清楚真正详细浅见解,为同事们的讨论,并指出错误。 首先,设计依据 火灾自动报警系统的设计是一家专业非常强的技术工作,同时还具有很强的政策性。因此,首先应明确以下设计依据: 第一,必须紧紧抓住的建筑设计防火标准,该系统的设计标准,标准的设备制造,安装施工审批标准和管理的法律和规章等五大方面的消防法律法规,并在实际了解国家有关本标准和标准积极字: “必须” , “必须假定” , “不适合” , “可能”和反面词: “严格禁止” , “不应该” , “没有” , “不适合“的含义。 第二,必须着眼于高层次的民间建筑的功能,利用和保护对象的防火等级,认真开展本标准和国家有关标准,认真对待公安防火监督部门的审批意见。 其次,火灾自动报警系统设备的建立 建立火灾探测器 要么全打开的印章或楼梯大厅应单独划分搜索范围,每个2 〜 3建立火灾探测器。 第一个房间(包括防前面的烟雾大厅楼梯前室,消防电梯间,消防电梯防前面房间烟雾楼梯大会堂来用场)和过道应区分单独划分搜索范围,特别是前面的房间,以及电梯,分散楼梯大厅和走道都是相互关联的,有时间的火灾烟雾比较容易收集或流动,是人员分散保存目标与防火,因此,应该安装火警探测器。关于共同电梯前室虽然不是人员分散,而且这方面的空间和良好的电梯是相互关联的,有时间的火灾烟雾也很容易被收集或流动,适当地划分为单独的搜索覆盖面和安装消防探测器。 电缆轴因此很容易形成掏出烟炎症渠道,拥有火灾时的火强度不容易延伸沿电缆燃烧,为此, “高级别民间建筑设计防火标准”和“民用建筑电气设计标准“分别提出了详细具体的规定,在建筑和在电线或电缆塑造。但认为具体实施的难度和目前的情况下,电缆竖井安装了火灾探测器是非常必要的,坐标轴的防火分隔要求,每2 〜 3或每一级安装。 电梯机房应安装火灾探测器,它的电梯是重要的垂直交通工具,其两个电梯机房已具有火灾危险性,其存在的三个基本解除以及打开洞,像打开闸门的水平之间的球洞,在气孔,持久的关系打开了洞与电梯机房或滑轮等,其时,有四个火,升降机以及往往成为火灾强度传播渠道,很容易危及电梯机房设施。因此,电梯机房建立了火灾探测器是必要的,也适用于皇冠建立火灾探测器举井。 2 ,手动火警报警按钮建立 (包括防前面的烟雾楼梯大厅鉴于各层前房间前面的房间,消防电梯间,消防电梯防这些烟雾楼梯大会堂派上用场前室)是有火灾时人员驱散节省目标,防火,应立即向警方举报的按钮,首选地点设立手动火警。此外,该室也应建立防火手册的共同电梯前,向警方报案的按钮。 在公共活动场所(包括会堂,礼堂,餐厅,多功能厅等)和主要通道等场所,是所有工作人员非常集中,主要是分散的渠道。因此,应立即向警方举报的按钮,在这些公共活动场所主要通道设立手册火灾;该手册规定的火灾中的主要通道报警按钮,以保证“ ,以手动火警最接近报警按钮距离防火区的任何位置不应该超过30米。 “ 第三,消防紧急广播喇叭建立 走道,大厅,餐厅等公共场所的工作人员都非常集中,主要是分散的渠道。因此,应该按这些公共场所的“最近的一项发言距离不超过25米的防火保护区的任何位置”和“在走道上不应大于十二点五米扬声器的过道末端距离”建立消防应急广播喇叭;下一步还应当建立消防在公共浴室的地方紧急广播喇叭。 第一个房间(包括防前面的烟雾大厅楼梯前室,消防电梯间,消防电梯防这些烟雾楼梯大会堂派上用场前室)是有火灾时的人员驱散节省目标与防火,也有分离和防火门的声音,人民的混乱和嘈杂,因此,应建立消防应急广播喇叭。在前面的共同电梯房也应建立消防应急广播喇叭。分散大厅楼梯也已经火灾时的人员驱散节省目标与防火,也是人民的声音和嘈杂的混淆,因此应建立消防应急广播喇叭,由主张消防紧急广播驱散指令。 第四,建立火灾报警装置 建立消防应急广播火灾自动报警系统,笔者认为还应该安装消防报警装置,但它的控制程序应该是:该报警器应确认火灾后,利用手动或自动控制模式统一消防相关区域传输预警,报警器停止工作时间的规定,迅速联系消防应急广播和电视节目,并且分散了人们的指示。 火警警报装置建立的立场,笔者认为应该向警方报案的按钮位置的手动火警是相同的,它的墙面安装应为距地面米高度 第五,消防专用电话设立 安装消防专用电话分机电话,应设机房其中也涉及一些人是在工作地点经常与消防联动控制(包括消防给水设备,备件发电机房,火柴变电站,主要ventilates空调引擎室,排放烟气轮机室,防火电梯机房及其他) ,消防控制系统的经营场所或设备的控制室,消防责任人员观察室,现场的安全管理等公共空间。轿车的影院中消防电梯和普通电梯应假设所有使用的特殊电话,请电梯机房和电梯轿车影院中,电梯机房及消防控制室,电梯轿车影院方块和消防控制室等三个成分是可靠的讲通信电话系统。通常在消防控制室;建立电梯监测演示板(包括位置指示器,显示方向灯,以讲信函电话,麻烦灯等) ,以进行必要的电梯在运行状态的监视和紧急情况下的控制。 配备了手动火警报警位置等按钮,消火栓按钮,还应该安装消防专用电话插座。 第三,消防联动控制 第一,消防联动控制应包括控制消防泵开启,停止,也应表现出的按钮,打开泵的位置和消防泵的工作和故障。当消火栓设有消火栓按钮时,其电气安装工程现场也应表现出的消防泵的工作模式有效状态(即建立消防泵工作表明灯) 。 第二,消防联动控制应包括控制喷洒水和水雾化灭火系统打开,停止,也应表现出的消防泵的工作和故障和流利显示,报警阀,安全信号阀工作模式积极的地位。此外,该盆地,水箱水位也应进行示范监测;为了防止检修信号阀关闭,作者认为应该使用带电信号控制信号阀证明它打开条件。 第三,消防联动控制其他控制和示范作用,应进行本标准和国家有关标准的具体规定。 第四,火灾自动报警系统布线 为了防止火灾发生时,消防控制,通信和警戒线遣散,使灭火工作无法进行,造成了更大的经济损失,也为抑制electronmagetic干扰(例如变压器,电电机,电缆等)的影响而产生的火灾自动报警系统。火灾自动报警系统的输电线路和消防控制,通信和预警线应使用被阻燃电缆,并应使用金属管或封闭式金属线槽保护。消防手册积极理事分期付款行应使用防火电缆,其电缆也应使用金属管或封闭式金属线槽保护。使用明复,应采取防火保护措施的金属管或封闭金属 ,结论备注 作者取决于具体的项目实施经验,阐述了设计依据,火灾自动报警设计和实际问题,以便建立系统设备,消防联动控制及其接线拿出一些肤浅的意见,其目的是增强了火灾自动报警系统的设计质量,早期发现,并通知消防,预防和减少火灾危害,通过保护个人和财产安全。 -----------希望可以符合要求--

158 评论

米苏and妮娜

我有一篇我本科毕设的小论文,英文中文都有,而且是我人工翻译的,8000字左右。你要的话PM我。我是电气工程及其自动化专业的。《Analysis of thyristor-controlled phase shifter applied in damping power system oscillations》

253 评论

相关问答

  • 电气英文原文论文文献

    你去知节网上找些,很多的,也很专业的!

    李晓诗125 7人参与回答 2023-12-08
  • 电气领域论文参考文献英文

    问题一:论文的外文参考文献从哪里找呢 在中国期刊网ki/里找,有那种英文的文献,之后翻译过来。万方、维普都可以。或者直接到外人数据库找。 APS美国物理学

    永远的怀念! 3人参与回答 2023-12-10
  • 电气自动化论文原理

    转眼间大学生活即将结束,毕业生要通过最后的毕业论文,毕业论文是一种比较正规的、比较重要的检验学生学习成果的形式,毕业论文我们应该怎么写呢?以下是我整理的电气自动

    美食风中沙鸥 3人参与回答 2023-12-07
  • 电气工程英文论文题目

    这类的选题有很多,在这里大家可以参考一下往期的论文选题,如:高功率引述整流器的建模与仿真、直流电机闭环控制调速系统的SIMULINK软件仿真、电力系统故障录波器

    我就叫小猪 5人参与回答 2023-12-08
  • 电气毕业论文中英版

    电气自动化应用逐渐深入人们日常的工作与生活之中,使人们的生活方式发生了巨大的变化,电气自动化就是电气信息及其自动化工程,常见的家用电器都与电气自动化息息相关。下

    开运潇潇 3人参与回答 2023-12-06